  • Stable long-life metal-oxide sensor
  • Range 0...1000 ppm NH3
  • Resolution 1 ppm NH3
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485
Description

Ammonia detector E2611-NH3 is a member of new PluraSens® family of multifunctional measurement instruments which is intended for detection of ammonia gas emissions in agriculture and refrigeration industries. 

Applications include poultry, dairy, cattle  farms, industrial refrigerators, where potentially dangerous concentration of NH3 can accumulate.

The instrument utilises a fully calibrated metal-oxide semiconductor gas sensor with excellent repeatability, stability and long lifetime.

Two relays with closing contact may be used for remote signalling or ventilation control. Two alarm set-points are user settable. Internal buzzer gives sound alarms.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.


Technical Data
Calibration ammonia NH3
Sensing method metal-oxide semiconductor
Sampling method diffusion
Detection range 0...1000 ppm NH3
Resolution 1 ppm NH3
Sensor lifetime > 5 years
Power supply 12...36 VDC (default)
24 VAC or 230 VAC as options
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Output relays 2 × SPST relays (closing contact),
250 VAC / 30 VDC, 5 A max
Alarms buzzer 85 dB
Default alarm set-points 25 ppm / 35 ppm NH3
Enclosure light-grey ABS plastic with ventilation slots, IP20
Dimensions H85 × W85 × D37 mm
Operating conditions -30...+70 °C, 0...95 %RH, non-condensing


Similar Products


E2611-CH4 - Methane Detector
E2611-CH4 - Methane Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1% LEL CH4
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2611-VOC - Solvent Vapor Detector
E2611-VOC - Solvent Vapor Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2611-HFC - Refrigerants Detector
E2611-HFC - Refrigerants Detector
  • Stable long-life metal-oxide sensor
  • Range 0...1000 ppm halocarbon gas
  • Resolution 1 ppm halocarbon gas
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2611-LEL - Combustible Gases Detector
E2611-LEL - Combustible Gases Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL
  • Resolution 0,1% LEL
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485