E2618-HFC

Refrigerant Transmitter
E2618-HFC
Features
  • Stable long-life metal-oxide sensor
  • Ranges 0...1000 / 0...2500 ppm halocarbon gas
  • Resolution 1 ppm halocarbon gas
  • 2 × 4-20 mA or 0-10 V, RS485
Description

Refrigerant transmitter E2618-HFC is a member of new PluraSens® family of multifunctional measurement instruments.

Applications include cold storage warehouses, skating arenas, and other areas, where leakages of halocarbon refrigerants are possible.

The instrument utilises a fully calibrated metal-oxide semiconductor gas sensor with excellent repeatability, stability and long lifetime. The sensor is highly sensitive to a wide range of CFC, HFC and HFO compounds, including R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234yf, R-1234ze and similar.

For demanding applications, a NDIR sensor is available on request.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.

Technical Data
Detected gases R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234yf, R-1234ze etc
Default calibration R-404a
Sensor type metal-oxide semiconductor
optical NDIR on demand
Sampling method diffusion
Detection ranges 0...1000 ppm halocarbon gas
0...2500 ppm halocarbon gas
Resolution 1 ppm halocarbon gas
Sensor lifetime >5 years
Power supply 12...36 VDC (default)
24 VAC as option
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H82 × W80 × D55 mm
Operating conditions -30...+70 °C, 0...95 %RH


Similar Products


E2618-CO - Carbon Monoxide Transmitter
E2618-CO - Carbon Monoxide Transmitter
  • Stable long-life electrochemical sensor
  • Range 0...300 or 0...1000 ppm CO
  • Resolution 1 ppm CO
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-NH3-E - Ammonia Transmitter
E2618-NH3-E - Ammonia Transmitter
  • Stable long-life electrochemical sensor
  • Range 0...100 / 0...300 / 0...1000 ppm NH3
  • Resolution 1 ppm NH3
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-CH4 - Methane Transmitter
E2618-CH4 - Methane Transmitter
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1 / 1 % LEL CH4
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-H2S - Hydrogen Sulfide Transmitter
E2618-H2S - Hydrogen Sulfide Transmitter
  • Stable long-life electrochemical sensor
  • Range 0...100 or 0...2000 ppm H2S
  • Resolution 1 ppm H2S
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-LEL - Combustible Gas Transmitter
E2618-LEL - Combustible Gas Transmitter
  • Stable long-life metal-oxide / pellistor gas sensor
  • Range 0...100% LEL
  • Resolution 0,1 / 1 % LEL
  • Wall mount or duct mount version
  • Attached or remote sensor
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-NO2 - Nitrogen Dioxide Transmitter
E2618-NO2 - Nitrogen Dioxide Transmitter
  • Stable long-life electrochemical sensor
  • Range 0...20 or 0...200 ppm NO2
  • Resolution 0,1 ppm or 1 ppm NO2
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-VOC - Solvent Vapors Transmitter
E2618-VOC - Solvent Vapors Transmitter
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-O3 - Ozone Transmitter
E2618-O3 - Ozone Transmitter
  • Stable long-life electrochemical sensor
  • Range 0...5 ppm or 0...1 ppm O3
  • Resolution 0,01 ppm O3
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-C2H4 - Ethylene Transmitter
E2618-C2H4 - Ethylene Transmitter
  • Humidity compensated electrochemical sensor
  • Range 0...10 / 0...200 / 0...1500 ppm C2H4
  • Resolution 0,1 / 1 / 1 ppm C2H4
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-SO2 - Sulfur dioxide Transmitter
E2618-SO2 - Sulfur dioxide Transmitter
  • Stable long-life electrochemical sensor
  • Range 0...50 or 0...2000 ppm SO2
  • Resolution 0,1 ppm or 1 ppm SO2
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-CL2 - Chlorine Transmitter
E2618-CL2 - Chlorine Transmitter
  • Stable long-life electochemical sensor
  • Range 0...10 ppm Cl2
  • Resoluton 0,1 ppm Cl2
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-ETO - Ethylene Oxide Transmitter
E2618-ETO - Ethylene Oxide Transmitter
  • Stable long-life electrochemical sensor
  • Range 0...20 or 0...100 ppm C2H4O
  • Resolution 0,1 ppm or 1 ppm C2H4O
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-NO - Nitric Oxide Transmitter
E2618-NO - Nitric Oxide Transmitter
  • Stable long-life electrochemical sensor
  • Detection range 0...250 ppm NO
  • Resolution 1 ppm NO
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-PID - Solvent Vapors Transmitter
E2618-PID - Solvent Vapors Transmitter
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-CO2 - Carbon Dioxide Transmitter
E2618-CO2 - Carbon Dioxide Transmitter
  • Stable long-life photoacoustic or optical NDIR sensor
  • Range 0...10 000 ppm / 40 000 ppm / 5 %vol CO2
  • Resolution 1 ppm / 10 ppm / 0.01 %vol CO2
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-O2 - Oxygen Transmitter
E2618-O2 - Oxygen Transmitter
  • Electrochemical sensor
  • Range 0...25 %vol O2
  • Resolution 0,01 %vol O2
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-N2O - Nitrous Oxide Transmitter
E2618-N2O - Nitrous Oxide Transmitter
  • Stable long-life optical NDIR gas sensor
  • Range 0...1000 ppm N2O
  • Resolution 1 ppm N2O
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-NH3-P - Ammonia Detector
E2618-NH3-P - Ammonia Detector
  • Stable long-life pellistor gas sensor
  • Range 0...15% vol. (0…100% LEL)
  • Resolution 0.1% vol. or 1% LEL
  • Wall mount or duct mount version
  • Attached or remote sensor
  • 2 × 4-20 mA or 0-10 V, RS485